Design features:
The KNF series anti-crystallization, idling and corrosion-resistant fluoroplastic pumps are deeply improved and optimized on the basis of the IHF series fluorine-lined centrifugal pumps, and inherit the IHFFluorine-lined centrifugal pump has the advantages of strong corrosion resistance, high mechanical strength, no aging, no toxin decomposition, etc., while solving a series of process problems such as crystallization, high temperature and idling, which greatly improves the service life and scope of application of the pump. The impeller and pump cover are pressed and molded by metal inserts and fluoroplastic. The shaft seal can be equipped with an external PTFE bellows mechanical seal or a cartridge water-cooled mechanical seal, and a variety of friction pair materials can meet the requirements of various working conditions.
Performance range
Design pressure: 1.6MPa Flow: 1~1400m3/h Head: 3~125m
Applicable temperature: -20°C~120°C, the temperature resistance of new materials can reach 180°C
Production implementation standard: GB/T3215-2019 or GB/T5656-2008, JB/T8688-2013
Model significance

Performance parameters
Table 1 2nd stage motor 2900r/min
Serial number | Model | Flow (m3/h) | Head (m) | Efficiency (%) | Motor power (kw) | NPSH (m) | Rotational speed (r/min) | Imports × exports (mm) |
1 | KNF25-20-125 | 1.5 | 22 | 25 | 1.1 | 2.5 | 2900 | 25×20 |
2 | 20 | 32 |
3 | 18 | 46 |
2 | KNF25-20-160 | 1.5 | 34 | 24 | 1.5 | 2.5 | 2900 | 25×20 |
2 | 32 | 30 |
3 | 30 | 38 |
3 | KNF25-20-200 | 1.5 | 52 | 20 | 4 | 2.5 | 2900 | 25×20 |
2 | 50 | 23 |
3 | 48 | 30 |
4 | KNF25-20-250 | 1.5 | 82 | 12 | 7.5 | 2.5 | 2900 | 25×20 |
2 | 80 | 18 |
3 | 78 | 26 |
5 | KNF32-25-125 | 2.5 | 22 | 35 | 1.5 | 2.5 | 2900 | 32×25 |
3.6 | 20 | 38 |
5 | 18 | 39 |
6 | KNF32-25-160 | 2.5 | 34 | 37 | 2.2 | 2.5 | 2900 | 32×25 |
3.6 | 32 | 39 |
5 | 30 | 40 |
7 | KNF32-25-200 | 2.5 | 52 | 32 | 4 | 2.5 | 2900 | 32×25 |
3.6 | 50 | 35 |
5 | 48 | 35 |
8 | KNF32-25-250 | 2.5 | 82 | 28 | 7.5 | 2.5 | 2900 | 32×25 |
3.6 | 80 | 31 |
5 | 78 | 30 |
9 | KNF40-25-125 | 4 | 22 | 35 | 1.5 | 3 | 2900 | 40×25 |
6.3 | 20 | 38 |
8 | 18 | 42 |
Serial number | Model | Flow (m3/h) | Head (m) | Efficiency (%) | Motor power (kw) | NPSH (m) | Rotational speed (r/min) | Imports × exports (mm) |
10 | KNF40-25-160 | 4 | 34 | 30 | 3 | 3 | 2900 | 40×25 |
6.3 | 32 | 31 |
8 | 30 | 32 |
11 | KNF40-25-200 | 4 | 52 | 20 | 5.5 | 3 | 2900 | 40×25 |
6.3 | 50 | 23 |
8 | 48 | 30 |
12 | KNF40-32-250 | 4 | 82 | 20 | 11 | 3 | 2900 | 40×25 |
6.3 | 80 | 24 |
8 | 78 | 34 |
13 | KNF50-32-125 | 8 | 22 | 48 | 2.2 | 3 | 2900 | 50×32 |
12.5 | 20 | 52 |
15 | 18 | 50 |
14 | KNF50-32-160 | 8 | 34 | 35 | 4 | 3 | 2900 | 50×32 |
12.5 | 32 | 47 |
15 | 30 | 47 |
15 | KNF50-32-200 | 8 | 52 | 28 | 7.5 | 3 | 2900 | 50×32 |
12.5 | 50 | 40 |
15 | 48 | 48 |
16 | KNF50-32-250 | 8 | 82 | 21 | 11 | 3 | 2900 | 50×32 |
12.5 | 80 | 34 |
15 | 78 | 38 |
17 | KNF50-32-315 | 8 | 115 | 20 | 30 | 3 | 2900 | 50×32 |
12.5 | 110 | 35 |
15 | 105 | 22 |
18 | KNF65-50-125 | 15 | 22 | 46 | 3 | 3.5 | 2900 | 65×50 |
25 | 20 | 61 |
30 | 18 | 67 |
19 | KNF65-50-160 | 15 | 34 | 45 | 5.5 | 3.5 | 2900 | 65×50 |
25 | 32 | 56 |
30 | 30 | 65 |
20 | KNF65-40-200 | 15 | 52 | 35 | 11 | 3.5 | 2900 | 65×40 |
25 | 50 | 51 |
30 | 48 | 48 |
21 | KNF65-40-250 | 15 | 82 | 33 | 18.5 | 3.5 | 2900 | 65×40 |
25 | 80 | 48 |
30 | 78 | 50 |
22 | KNF65-40-315 | 15 | 115 | 35 | 30 | 3.5 | 2900 | 65×40 |
25 | 110 | 40 |
30 | 105 | 42 |
23 | KNF80-65-125 | 35 | 22 | 52 | 5.5 | 4 | 2900 | 80×65 |
50 | 20 | 65 |
60 | 18 | 70 |
24 | KNF80-65-160 | 35 | 34 | 60 | 11 | 4 | 2900 | 80×65 |
50 | 32 | 60 |
60 | 30 | 64 |
25 | KNF80-50-200 | 35 | 52 | 53 | 15 | 4 | 2900 | 80×50 |
50 | 50 | 55 |
60 | 48 | 63 |
26 | KNF80-50-250 | 35 | 82 | 48 | 30 | 4 | 2900 | 80×50 |
50 | 80 | 56 |
60 | 78 | 50 |
27 | KNF80-50-315 | 35 | 115 | 45 | 37 | 4 | 2900 | 80×50 |
50 | 110 | 50 |
60 | 105 | 48 |
28 | KNF100-80-125 | 65 | 22 | 62 | 11 | 4.5 | 2900 | 100×80 |
100 | 20 | 65 |
110 | 18 | 68 |
Serial number | Model | Flow (m3/h) | Head (m) | Efficiency (%) | Motor power (kw) | NPSH (m) | Rotational speed (r/min) | Imports × exports (mm) |
29 | KNF100-80-160 | 65 | 34 | 65 | 15 | 4.5 | 2900 | 100×80 |
100 | 32 | 70 |
110 | 30 | 65 |
30 | KNF100-65-200 | 65 | 52 | 62 | 30 | 4.5 | 2900 | 100×65 |
100 | 50 | 68 |
110 | 48 | 56 |
31 | KNF100-65-250 | 65 | 82 | 60 | 45 | 4.5 | 2900 | 100×65 |
100 | 80 | 65 |
110 | 78 | 70 |
32 | KNF100-65-315 | 65 | 115 | 55 | 75 | 4.5 | 2900 | 100×65 |
100 | 110 | 60 |
110 | 105 | 58 |
33 | KNF125-80-160 | 100 | 38 | 57 | 30 | 5 | 2900 | 125×80 |
160 | 32 | 64 |
180 | 26 | 52 |
34 | KNF125-100-200 | 120 | 55 | 63 | 55 | 5 | 2900 | 125×100 |
200 | 50 | 65 |
220 | 45 | 62 |
35 | KNF125-100-250 | 120 | 88 | 54 | 75 | 5 | 2900 | 125×100 |
200 | 80 | 68 |
220 | 75 | 61 |
Table 2 Four-stage motor 1450r/min
Serial number | Model | Flow (m3/h) | Head (m) | Efficiency (%) | Motor power (kw) | NPSH (m) | Rotational speed (r/min) | Imports × exports (mm) |
1 | KNF25-20-125 | 0.75 | 5.5 | 15 | 0.37 | 2.5 | 1450 | 25×20 |
1 | 5 | 17 |
1.5 | 4.5 | 21 |
2 | KNF25-20-160 | 0.75 | 8.5 | 16 | 0.37 | 2.5 | 1450 | 25×20 |
1 | 8 | 18 |
1.5 | 7.5 | 24 |
3 | KNF25-20-200 | 0.75 | 13 | 15 | 0.55 | 2.5 | 1450 | 25×20 |
1 | 12.5 | 18 |
1.5 | 12 | 24 |
4 | KNF25-20-250 | 0.75 | 20.5 | 11 | 1.5 | 2.5 | 1450 | 25×20 |
1 | 20 | 16 |
1.5 | 19.5 | 24 |
5 | KNF32-25-125 | 1.2 | 5.5 | 32 | 0.55 | 2.5 | 1450 | 32×25 |
1.8 | 5 | 38 |
2.5 | 4.5 | 41 |
6 | KNF32-25-160 | 1.2 | 8.5 | 33 | 0.55 | 2.5 | 1450 | 32×25 |
1.8 | 8 | 39 |
2.5 | 7.5 | 41 |
7 | KNF32-25-200 | 1.2 | 13 | 15 | 0.75 | 2.5 | 1450 | 32×25 |
1.8 | 12.5 | 18 |
2.5 | 12 | 19.5 |
8 | KNF32-25-250 | 1.2 | 20.5 | 15 | 1.5 | 2.5 | 1450 | 32×25 |
1.8 | 20 | 18 |
2.5 | 19.5 | 24 |
9 | KNF40-25-125 | 2 | 5.5 | 26 | 0.55 | 3 | 1450 | 40×25 |
3 | 5 | 28 |
4 | 4.5 | 32 |
10 | KNF40-25-160 | 2 | 8.5 | 29 | 0.55 | 3 | 1450 | 40×25 |
3 | 8 | 31 |
4 | 7.5 | 33 |
Serial number | Model | Flow (m3/h) | Head (m) | Efficiency (%) | Motor power (kw) | NPSH (m) | Rotational speed (r/min) | Imports × exports (mm) |
11 | KNF40-25-200 | 2 | 13 | 19 | 0.75 | 3 | 1450 | 40×25 |
3 | 12.5 | 23 |
4 | 12 | 24 |
12 | KNF40-32-250 | 2 | 20.5 | 15 | 1.5 | 3 | 1450 | 40×25 |
3 | 20 | 20 |
4 | 19.5 | 30 |
13 | KNF50-32-125 | 4 | 5.5 | 47 | 0.55 | 3 | 1450 | 50×32 |
6 | 5 | 52 |
8 | 4.5 | 50 |
14 | KNF50-32-160 | 4 | 8.5 | 35 | 0.55 | 3 | 1450 | 50×32 |
6 | 8 | 47 |
8 | 7.5 | 47 |
15 | KNF50-32-200 | 4 | 13 | 28 | 1.1 | 3 | 1450 | 50×32 |
6 | 12.5 | 40 |
8 | 12 | 48 |
16 | KNF50-32-250 | 4 | 20.5 | 21 | 1.5 | 3 | 1450 | 50×32 |
6 | 20 | 34 |
8 | 19.5 | 38 |
17 | KNF50-32-315 | 4 | 29 | 39 | 5.5 | 3 | 1450 | 50×32 |
6 | 28 | 50 |
8 | 26 | 56 |
18 | KNF65-50-125 | 8 | 5.5 | 46 | 0.55 | 3.5 | 1450 | 65×50 |
12.5 | 5 | 61 |
15 | 4.5 | 67 |
19 | KNF65-50-160 | 8 | 8.5 | 45 | 1.1 | 3.5 | 1450 | 65×50 |
12.5 | 8 | 56 |
15 | 7.5 | 65 |
20 | KNF65-40-200 | 8 | 13 | 35 | 1.5 | 3.5 | 1450 | 65×40 |
12.5 | 12.5 | 51 |
15 | 12 | 48 |
21 | KNF65-40-250 | 8 | 20.5 | 33 | 3 | 3.5 | 1450 | 65×40 |
12.5 | 20 | 48 |
15 | 19.5 | 50 |
22 | KNF65-40-315 | 8 | 29 | 35 | 5.5 | 3.5 | 1450 | 65×40 |
12.5 | 28 | 40 |
15 | 26 | 38 |
23 | KNF80-65-125 | 18 | 5.5 | 52 | 1.1 | 4 | 1450 | 80×65 |
25 | 5 | 65 |
30 | 4.5 | 70 |
24 | KNF80-65-160 | 18 | 8.5 | 60 | 1.5 | 4 | 1450 | 80×65 |
25 | 8 | 64 |
30 | 7.5 | 53 |
25 | KNF80-50-200 | 18 | 13 | 55 | 2.2 | 4 | 1450 | 80×50 |
25 | 12.5 | 63 |
30 | 12 | 55 |
26 | KNF80-50-250 | 18 | 20.5 | 48 | 5.5 | 4 | 1450 | 80×50 |
25 | 20 | 56 |
30 | 19.5 | 50 |
27 | KNF80-50-315 | 18 | 29 | 45 | 7.5 | 4 | 1450 | 80×50 |
25 | 28 | 50 |
30 | 26 | 48 |
28 | KNF100-80-125 | 35 | 5.5 | 62 | 1.5 | 2.5 | 1450 | 100×80 |
50 | 5 | 65 |
55 | 4.5 | 68 |
29 | KNF100-80-160 | 35 | 8.5 | 65 | 2.2 | 2.5 | 1450 | 100×80 |
50 | 8 | 70 |
55 | 7.5 | 65 |
Serial number | Model | Flow (m3/h) | Head (m) | Efficiency (%) | Motor power (kw) | NPSH (m) | Rotational speed (r/min) | Imports × exports (mm) |
30 | KNF100-65-200 | 35 | 13 | 62 | 5.5 | 2.5 | 1450 | 100×65 |
50 | 12.5 | 68 |
55 | 12 | 56 |
31 | KNF100-65-250 | 35 | 20.5 | 60 | 7.5 | 2.5 | 1450 | 100×65 |
50 | 20 | 65 |
55 | 19.5 | 70 |
32 | KNF100-65-315 | 35 | 29 | 55 | 11 | 2.5 | 1450 | 100×65 |
50 | 28 | 60 |
55 | 26 | 58 |
33 | KNF125-80-160 | 50 | 10 | 57 | 5.5 | 3 | 1450 | 125×80 |
80 | 8 | 64 |
90 | 6 | 52 |
34 | KNF125-100-200 | 60 | 14 | 63 | 11 | 3 | 1450 | 125×100 |
100 | 12.5 | 65 |
110 | 11 | 60 |
35 | KNF125-100-250 | 60 | 22 | 53 | 15 | 3 | 1450 | 125×100 |
100 | 20 | 65 |
120 | 9.5 | 62 |
36 | KNF125-100-315 | 60 | 34 | 55 | 22 | 5 | 1450 | 125×100 |
100 | 32 | 60 |
120 | 31 | 62 |
37 | KNF125-100-400 | 60 | 52 | 63 | 37 | 3 | 1450 | 125×100 |
100 | 50 | 75 |
120 | 48 | 72 |
38 | KNF150-125-250 | 120 | 22 | 60 | 22 | 5 | 1450 | 150×125 |
200 | 20 | 65 |
240 | 18 | 64 |
39 | KNF150-125-315 | 120 | 34 | 54 | 45 | 5 | 1450 | 150×125 |
200 | 32 | 63 |
240 | 30 | 62 |
40 | KNF150-125-400 | 120 | 53 | 50 | 75 | 5 | 1450 | 150×125 |
200 | 50 | 62 |
240 | 48 | 62 |
41 | KNF200-150-250 | 240 | 22 | 50 | 45 | 5.5 | 1450 | 200×150 |
400 | 20 | 63 |
480 | 18 | 62 |
42 | KNF200-150-315 | 240 | 35 | 55 | 75 | 5.5 | 1450 | 200×150 |
400 | 32 | 64 |
480 | 29 | 63 |
43 | KNF200-150-400 | 240 | 55 | 50 | 110 | 5.5 | 1450 | 200×150 |
400 | 50 | 62 |
480 | 45 | 62 |
44 | KNF250-200-250 | 500 | 22 | 55 | 55 | 6 | 1450 | 250×200 |
650 | 20 | 60 |
750 | 18 | 58 |
45 | KNF250-200-315 | 500 | 34 | 55 | 90 | 6 | 1450 | 250×200 |
650 | 32 | 60 |
750 | 29 | 58 |
46 | KNF250-200-400 | 500 | 55 | 59 | 160 | 6 | 1450 | 250×200 |
650 | 50 | 72 |
750 | 42 | 71 |
47 | KNF300-250-315 | 800 | 35 | 68 | 220 | 7 | 1450 | 300×250 |
1000 | 32 | 70 |
1200 | 26 | 75 |
48 | KNF300-250-400 | 800 | 55 | 65 | 250 | 7 | 1450 | 300×250 |
1000 | 50 | 78 |
1200 | 42 | 75 |
Selection Notes
Body Material | The main body of the conventional pump type is made of steel lining F46. Temperature resistance range: -20°C~120°C. If the operating temperature is greater than 120°C, high-temperature resistant materials should be selected. |
Impeller structure | The conventional pump impeller structure is closed. If the liquid contains particulate impurities or crystallization, an open impeller is required. |
Mechanical seals | The conventional configuration is an externally mounted PTFE bellows mechanical seal, if the operating temperature is greater than 100 °C, or there are particle impurities and crystallization in the liquid, it is necessary to configure a cartridge water-cooled mechanical seal. The flushing scheme can be plan23, plan53, plan54, etc. |
Performance options (Customized on demand) | (1) High temperature resistant material (2) Thermal insulation pump body (3) Flushing scheme (4) Diaphragm coupling (5) Motor designated brand, or frequency conversion motor (6) Underload/overload/missing item protector (7) If you have other requirements, please contact our sales department |
Attention to selection
1. The content of hard solid particles in the liquid should not be too much;
2. For liquids that are easy to crystallize, it is necessary to consider the insulation measures of pipelines and pumps, as well as anti-crystallization seals;
3. Valves need to be installed in the inlet and outlet pipelines of the pump, and the valves of the inlet pipelines are fully open normally and closed during general maintenance. The outlet pipeline valve is used to regulate the flow rate, and the outlet pipeline should be equipped with a check valve, if the check valve is not installed, the outlet pipeline valve should be closed before stopping the pump to prevent water hammer from damaging the pump;
4. The long-term operating flow rate should be 35%~110% of the rated flow rate of the pump, and too high or too low will affect the service life of the pump;
5. When the density of the conveying medium exceeds 1250kg/m3 (different pumps are slightly different), it is necessary to inform the sales department of our company that the power of the supporting motor needs to be adjusted;
6. The composition of the conveying medium should be informed to the sales department of our company, so as to select a more suitable machine seal and material.
List of consumables
The name of the consumable | illustrate |
impeller | The wearing parts are mainly mechanical seals and auxiliary matching parts, and the selection of mechanical seals of centrifugal pumps is very important, which can greatly improve the service life. Dry grinding of mechanical seals, conveying high solid media, high temperature, high pressure, and inadequate installation will reduce the service life. |
Mechanical seals |
Pump cover |
Machine sealed glands |
Tighten the bolts |