Design features:
CQB-F series fluoroplastic magnetic drive centrifugal pump adopts magnetic coupling transmission, and the leak-proof design cancels the shaft seal, eliminates the trouble of dripping, and does not pollute the use site. Its overflow parts are made of fluoroplastics and high-purity technical ceramics. It has excellent corrosion resistance and sealing, and can continuously convey any concentration of acid, alkali, strong oxidant and other corrosive media without damage.
Performance range
Flow: 0.5~200m3/h Head: 8~80m
Operating temperature: -20°C~120°C. The new material is used to withstand temperatures up to 180°C
Production execution standard: JB/T7742-2013
Model significance

Performance parameters
Table 1 Full shaping
Serial number | Model | Flow (m3/h) | Head (m) | Efficiency (%) | Motor power (kw) | NPSH (m) | Rotational speed (r/min) | Imports × exports (mm) |
1 | CQB16-12-50F | 0.5 | 2 | 8 | 0.025 | 9 | 2900 | 16×12 |
0.8 | 1.5 | 10 |
2 | CQB15-15-65F | 0.8 | 3.5 | 16 | 0.18 | 6 | 15×15 |
1 | 2.8 | 18 |
3 | CQB20-15-75F | 1.6 | 7 | 20 | 0.18 | 6 | 20×15 |
1.8 | 6 | 22 |
4 | CQB25-20-100F | 2.5 | 10 | 28 | 0.37 | 6 | 25×20 |
5 | CQB32-20-110F | 4 | 13.5 | 30 | 0.55 | 6 | 32×20 |
5.5 | 13 | 35 |
6 | CQB32-20-125F | 2.5 | 21 | 36 | 0.75 | 6 | 32×20 |
3.6 | 20 | 38 |
7 | CQB40-25-120F | 6.3 | 15 | 42 | 0.75 | 5 | 40×25 |
8 | CQB40-25-125F | 6.3 | 20 | 41 | 1.1 | 4.5 | 40×25 |
9 | CQB40-40-125F | 6.3 | 17.5 | 42 | 1.1 | 4 | 40×40 |
10 | CQB50-32-125F | 12.5 | 30 | 42 | 1.5 | 3.5 | 50×32 |
Table 2 Steel lining type
Serial number | Model | Flow (m3/h) | Head (m) | Efficiency (%) | Motor power (kw) | NPSH (m) | Rotational speed (r/min) | Imports × exports (mm) |
1 | CQB25-20-125F | 1.5 | 22 | 18 | 1.1 | 2.5 | 2900 | 25×20 |
2 | 20 | 20 |
3 | 19 | 24 |
2 | CQB25-20-160F | 1.5 | 34 | 19 | 1.5 | 2.5 | 2900 | 25×20 |
2 | 32 | 22 |
3 | 30 | 25 |
3 | CQB25-20-200F | 1.5 | 52 | 18 | 4 | 2.5 | 2900 | 25×20 |
2 | 50 | 20 |
3 | 48 | 22 |
4 | CQB32-20-125F | 2 | 22 | 20.5 | 1.5 | 2.5 | 2900 | 32×20 |
3.2 | 20 | 20 |
5 | 19 | 18 |
5 | CQB32-20-160F | 2 | 34 | 36 | 2.2 | 2.5 | 2900 | 32×20 |
3.2 | 32 | 38 |
5 | 30 | 42 |
6 | CQB32-20-200F | 2 | 52 | 32 | 4 | 2.5 | 2900 | 32×20 |
3.2 | 50 | 36 |
5 | 48 | 34 |
7 | CQB40-25-160F | 4 | 33 | 32 | 3 | 2.5 | 2900 | 40×25 |
6.3 | 32 | 36 |
8 | 29 | 39 |
8 | CQB40-25-200F | 4 | 51 | 21 | 5.5 | 2.5 | 2900 | 40×25 |
6.3 | 50 | 25 |
8 | 48 | 28 |
9 | CQB50-32-125F | 7 | 22 | 28 | 1.5 | 2.5 | 2900 | 50×32 |
12.5 | 20 | 42 |
15 | 19 | 46 |
10 | CQB50-32-160F | 7 | 33 | 30 | 4 | 2.5 | 2900 | 50×32 |
12.5 | 32 | 39 |
15 | 27 | 41 |
11 | CQB50-32-200F | 7 | 52 | 20 | 7.5 | 2.5 | 2900 | 50×32 |
12.5 | 50 | 31 |
15 | 45 | 35 |
12 | CQB65-50-125F | 15 | 21 | 46 | 4 | 3 | 2900 | 65×50 |
20 | 20 | 61 |
25 | 15 | 67 |
13 | CQB65-50-160F | 15 | 33 | 38 | 5.5 | 3 | 2900 | 65×50 |
20 | 32 | 40 |
25 | 28 | 47 |
14 | CQB65-40-200F | 15 | 51 | 41 | 11 | 3 | 2900 | 65×40 |
20 | 50 | 48 |
25 | 49 | 54 |
15 | CQB65-40-250F | 15 | 81 | 35 | 18.5 | 4 | 2900 | 65×40 |
25 | 80 | 41 |
30 | 75 | 44 |
Serial number | Model | Flow (m3/h) | Head (m) | Efficiency (%) | Motor power (kw) | NPSH (m) | Rotational speed (r/min) | Imports × exports (mm) |
16 | CQB80-65-125F | 35 | 22 | 51 | 7.5 | 4 | 2900 | 80×65 |
50 | 20 | 56 |
60 | 15 | 55 |
17 | CQB80-65-160F | 35 | 34 | 45 | 11 | 4 | 2900 | 80×65 |
50 | 32 | 60 |
60 | 28 | 52 |
18 | CQB80-50-200F | 35 | 52 | 50 | 18.5 | 4 | 2900 | 80×50 |
50 | 50 | 60 |
60 | 45 | 60 |
19 | CQB80-50-250F | 35 | 82 | 45 | 30 | 4 | 2900 | 80×50 |
50 | 80 | 51 |
60 | 75 | 53 |
20 | CQB100-80-125F | 65 | 22 | 53 | 11 | 5 | 2900 | 100×80 |
100 | 20 | 62 |
120 | 18 | 63 |
21 | CQB100-80-160F | 65 | 34 | 53 | 18.5 | 5 | 2900 | 100×80 |
100 | 32 | 58 |
120 | 30 | 60 |
22 | CQB100-65-200F | 70 | 52 | 55 | 30 | 5 | 2900 | 100×65 |
100 | 50 | 61 |
120 | 46 | 64 |
23 | CQB100-65-250F | 70 | 82 | 60 | 45 | 5 | 2900 | 100×65 |
100 | 80 | 68 |
120 | 75 | 67 |
24 | CQB125-100-160F | 80 | 9 | 56 | 11 | 5 | 1450 | 125×100 |
100 | 8 | 64 |
120 | 7 | 65 |
25 | CQB125-100-200F | 80 | 14 | 63 | 11 | 5 | 1450 | 125×100 |
100 | 12.5 | 75 |
120 | 11 | 74 |
26 | CQB125-100-250F | 80 | 22 | 54 | 15 | 5 | 1450 | 125×100 |
100 | 20 | 65 |
120 | 18 | 66 |
27 | CQB150-125-200F | 150 | 14 | 58 | 18.5 | 5 | 1450 | 150×125 |
200 | 12.5 | 62 |
240 | 11 | 62 |
28 | CQB150-125-250F | 150 | 21 | 61 | 22 | 5 | 1450 | 150×125 |
200 | 20 | 67 |
240 | 19 | 63 |
29 | CQB200-150-250F | 300 | 21 | 67 | 45 | 5.5 | 1450 | 200×150 |
400 | 20 | 79 |
480 | 19 | 77 |
Selection Notes
Body Material | The main body of the conventional pump type is made of steel lining F46. Temperature resistance range: -20°C~120°C. If the operating temperature is greater than 120°C, high-temperature resistant materials should be selected. |
Internal and external magnets | Rare earth permanent magnets are used. Working under the design conditions, there is no demagnetization and demagnetization over time. However, demagnetization and demagnetization may occur when the pump is overloaded, stalled, and the temperature is higher than the design conditions. |
Sealing material | The magnetic pump is driven by magnetic coupling, so there are no moving seals. Static seals include O-rings, isolation sleeves and reinforcing sleeves. /b12>The O-ring is generally made of fluorine rubber, the isolation sleeve is made of F46 material, and the reinforcing sleeve is a non-metallic material with high resistance and high rigidity, which effectively avoids the phenomenon of magnetic eddy current. Other materials can also be selected according to the characteristics of the material. |
Bushing material | The shaft sleeve can be made of SiC, SSIC, modified carbon fiber and other materials, which can be selected according to different working conditions. It has excellent wear resistance and corrosion resistance. |
Performance options (Customized on demand) | (1) High temperature resistant material (2) Thermal insulation pump body (3) Diaphragm coupling (4) Motor designated brand, or frequency conversion motor (5) Underload/Overload/Missing Protector (6) If you have other requirements, please contact our sales department |
Attention to selection
1. If the liquid contains solid particles or crystals, please use KCF fluorine-lined magnetic pump;
2. Valves need to be installed in the inlet and outlet pipelines of the pump, and the valves of the inlet pipelines are fully open normally and closed during general maintenance. The outlet pipeline valve is used to regulate the flow rate, and the outlet pipeline should be equipped with a check valve, if the check valve is not installed, the outlet pipeline valve should be closed before stopping the pump to prevent water hammer from damaging the pump;
3. The long-term operating flow rate should be 35%~110% of the rated flow rate of the pump, and too high or too low will affect the service life of the pump;
4. When the density of the conveying medium exceeds 1250kg/m3 (slightly different pumps), it is necessary to inform the sales department of our company that the magnetic coupler needs to be designed separately, and the power of the supporting motor needs to be adjusted;
5. The composition of the conveying medium should be informed to the sales department of our company, so as to select more suitable parts and materials.
List of consumables
The name of the consumable | illustrate |
Impeller mouth ring | Wearing parts are moving parts and friction parts, and regular maintenance and maintenance can greatly improve the service life of the whole machine. It is recommended to check every 1500 hours when the system is on for 24 hours. It is recommended to check the working condition of the machine frequently once a month. It is recommended to check once before starting up the working condition after a long shutdown. |
Rotor |
Plain bearing |
Spacer sleeve |
Dead ring |
Pump cover |